AS ISO 13485:2017

[Current]

Medical devices — Quality management systems — Requirements for regulatory processes

Adopts ISO 13485:2016 to specify requirements for a quality management system where an organization needs to demonstrate its ability to provide medical devices and related services that consistently meet customer and applicable regulatory requirements.
Published: 14/12/2017
Pages: 35
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management system
4.1 General requirements
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.2 Documentation requirements
4.2.1 General
4.2.2 Quality manual
4.2.3 Medical device file
4.2.4 Control of documents
4.2.5 Control of records
5 Management responsibility
5.1 Management commitment
5.2 Customer focus
5.3 Quality policy
5.4 Planning
5.4.1 Quality objectives
5.4.2 Quality management system planning
5.5 Responsibility, authority and communication
5.5.1 Responsibility and authority
5.5.2 Management representative
5.5.3 Internal communication
5.6 Management review
5.6.1 General
5.6.2 Review input
5.6.3 Review output
6 Resource management
6.1 Provision of resources
6.2 Human resources
6.3 Infrastructure
6.4 Work environment and contamination control
6.4.1 Work environment
6.4.2 Contamination control
7 Product realization
7.1 Planning of product realization
7.2 Customer-related processes
7.2.1 Determination of requirements related to product
7.2.2 Review of requirements related to product
7.2.3 Communication
7.3 Design and development
7.3.1 General
7.3.2 Design and development planning
7.3.3 Design and development inputs
7.3.4 Design and development outputs
7.3.5 Design and development review
7.3.6 Design and development verification
7.3.7 Design and development validation
7.3.8 Design and development transfer
7.3.9 Control of design and development changes
7.3.10 Design and development files
7.4 Purchasing
7.4.1 Purchasing process
7.4.2 Purchasing information
7.4.3 Verification of purchased product
7.5 Production and service provision
7.5.1 Control of production and service provision
7.5.2 Cleanliness of product
7.5.3 Installation activities
7.5.4 Servicing activities
7.5.5 Particular requirements for sterile medical devices
7.5.6 Validation of processes for production and service provision
7.5.7 Particular requirements for validation of processes for sterilization and sterile barrier systems
7.5.8 Identification
7.5.9 Traceability
7.5.9.1 General
7.5.9.2 Particular requirements for implantable medical devices
7.5.10 Customer property
7.5.11 Preservation of product
7.6 Control of monitoring and measuring equipment
8 Measurement, analysis and improvement
8.1 General
8.2 Monitoring and measurement
8.2.1 Feedback
8.2.2 Complaint handling
8.2.3 Reporting to regulatory authorities
8.2.4 Internal audit
8.2.5 Monitoring and measurement of processes
8.2.6 Monitoring and measurement of product
8.3 Control of nonconforming product
8.3.1 General
8.3.2 Actions in response to nonconforming product detected before delivery
8.3.3 Actions in response to nonconforming product detected after delivery
8.3.4 Rework
8.4 Analysis of data
8.5 Improvement
8.5.1 General
8.5.2 Corrective action
8.5.3 Preventive action
Annex A
Annex B
Bibliography
Cited references in this standard
[Current]
Quality management systems — Fundamentals and vocabulary
Content history
[Superseded]
DR AS ISO 13485:2017
$161.10
AUD
Inclusive of GST
Available formats
iconCreated with Sketch.
Available formats
icon_export/16/closeCreated with Sketch.
Web Reader
Instantly view standards in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader (PDF)
View standards in PDF format in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader
Licence:
1 user
Total
$161.10
Add to cart
visa logo
mastercard logo
amex logo