Standard
Track updates
AS/NZS ISO 16900.5:2021
[Current]Respiratory protective devices — Methods of test and test equipment, Method 5: Breathing machine, metabolic simulator, RPD headforms and torso, tools and verification tools
Identically adopts ISO 16900-5:2016 and its Amendment No. 1 (2018) for Australia and New Zealand, which specifies the characteristics of breathing machines, metabolic simulators, RPD head forms/torso, RPD tools and RPD verification tools that are common to RPD test laboratories.
Published: 18/06/2021
Pages: 36
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Description of test equipment
4.1 RPD head forms
4.1.1 General
4.1.2 RPD head form CAD files
4.1.3 Surface finish and materials of construction
4.1.4 Trachea tube assembly and interface connections
4.2 RPD torso
4.3 Breathing machine
4.4 Metabolic simulator
4.5 Performance requirements of breathing machines and metabolic simulators
4.5.1 General
4.5.2 Minute ventilation
4.5.3 Ventilation setting switching
4.5.4 Output characteristics
4.6 RPD verification tools
4.6.1 General
4.6.2 Verification orifices
4.6.3 Verification orifice adapter
4.6.4 Verification procedure for work of breathing
4.6.5 RPD carbon dioxide verification tube and verification tube adapter
4.7 RPD tools
4.7.1 Filter simulator
4.7.2 Fx force probe
4.7.3 Exposed surface identification probe
Annex A
A.1 General
A.2 Background
A.3 Equipment and configuration
A.4 Example
A.5 Procedure
A.6 Acceptable leakage limit
Bibliography
Amendment 1 — RPD head forms front and side view
Cited references in this standard
[Superseded]
Respiratory protective devices — Human factors — Part 2: Anthropometrics
[Current]
Respiratory protective devices - Performance requirements - Part 3: Thread connection
[Current]
Respiratory protective devices - Methods of test and test equipment - Part 12: Determination of volume-averaged work of breathing and peak respiratory pressures
[Current]
Respiratory protective devices - Methods of test and test equipment - Part 9: Determination of carbon dioxide content of the inhaled gas
Content history
[Current]
[Current]
DR AS/NZS ISO 16900.5:2021
One-time Purchase
Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^
$135.33 AUD
Inclusive of GSTFormat *
Web Reader
Licenses *
1 user
Total$135.33 AUD
IMPORTANT