AS/NZS 3002:2008

[Available Superseded]

Electrical installations — Shows and carnivals

This Standard sets out requirements for the supply of electricity at low-voltage by wiring distribution systems to power consuming devices used for accommodation, entertainment or display purposes within concessions, tents, living quarters and other structures, associated with events with a maximum duration of four weeks.
Published: 05/12/2008
Pages: 22
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
1 Scope and general
1.1 Scope
1.2 Application
1.3 Referenced documents
1.4 Definitions
2 Permanent site low-voltage electrical installation
2.1 Method of supply
2.1.1 General
2.1.2 Underground wiring
2.1.3 Overhead wiring
2.2 Maximum demand
2.3 Connection facilities
2.3.1 General
2.3.2 Enclosure
2.3.3 Socket-outlets
2.3.4 Other connection facilities
2.3.5 Overload protection
2.3.6 RCD Protection
2.3.7 Control and isolation
2.4 Switchboards
2.4.1 General
2.4.2 Enclosure
2.5 Location and mounting of switchboard enclosures
 
2.5.1.1 General
2.5.1.2 Mounting height
2.5.2 Socket-outlets
2.5.3 Identification
3 Supply by generating/inverter plant
3.1 General
3.2 Generating sets
3.3 Inverters
3.4 RCD type for generator sets and switchboards
3.4.1 In New Zealand
4 Temporary distribution systems and electrical equipment
4.1 General
4.2 Cable
4.2.1 Cable selection
4.2.2 Installation of cables
4.2.3 Connection of cables
4.2.3.1 Direct connections
4.2.3.2 Detachable connections
4.2.3.2.1 Specifications
4.2.3.2.2 Limitation of current for detachable connections
4.3 Cascadable reticulation units
4.3.1 General
4.3.2 Enclosure
4.3.3 Location and mounting of cascadable reticulation units
4.3.3.1 General
4.3.3.2 Socket-outlets
4.4 Outlet boxes
4.4.1 General
4.4.2 Construction
4.4.3 Termination of supply lead
4.4.4 Socket-outlets
4.4.5 Earthing
4.4.6 Overcurrent protection
4.4.6.1 General
4.4.6.2 Rating
4.4.6.3 Operation
4.4.7 Protection against earth leakage current
4.4.8 Control switches
4.4.9 Marking
4.5 Electrical portable outlet devices
4.5.1 General
4.5.2 Connection to low-voltage electrical power supply
4.5.3 Location
4.5.4 Protection against earth leakage current
4.6 Festoon and decorative lighting
4.6.1 General
4.6.2 Clearances
4.6.3 Loading of final subcircuits
4.6.4 Decorative lighting outfits
4.6.5 Protection against earth leakage current
4.7 Riding devices
Appendix A
A1 Scope
A2 Personnel
A3 Verification
A4 Testing of residual current devices (RCDs)
A5 Periodic verification (fixed installation)
A6 Periodic verification (fittings)
A7 Periodic verification certification (New Zealand only)
A8 Certificate of verification
Appendix B
Cited references in this standard
Content history
[Superseded]
DR 06738