Standard
Track updates
iconCreated with Sketch.

AS/NZS 3001.1:2022

[Current]

Electrical installations - Connectable electrical installations and supply arrangements, Part 1: Site supplies for connectable electrical installations

Included in Electrical installation set
Sets out requirements for electrical installations associated with site supplies for connectable electrical installations that are intended for connection to low voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.)
Published: 18/11/2022
Pages: 37
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Introduction
1 Scope and general
1.1 Scope
1.1.1 General
1.1.2 Inclusions
1.1.3 Exclusions
1.2 Application
1.3 Normative references
1.4 Terms and definitions
1.5 Alterations and repairs
1.5.1 Alterations
1.5.2 Repairs
2 Supply arrangements for connectable electrical installations
2.1 Supply arrangements in caravan parks
2.1.1 General
2.1.2 Supplies
2.1.3 Supply to service pillars
2.1.4 Common submains
2.1.5 Ring circuits
2.2 Switchboards
2.3 Wiring systems
2.3.1 General
2.3.2 Underground wiring
2.3.2.1 Underground wiring for site supplies
2.3.2.2 Spacing from other underground services
2.3.2.3 Identification of underground wiring providing site supply
2.3.2.4 Recording and marking of underground cable location
2.3.3 Aerial wiring systems
2.3.3.1 General
2.3.3.2 Aerial wiring systems
2.3.4 Catenary wiring systems
2.3.4.1 Types of cables
2.3.4.2 Catenary supports
2.3.4.3 Clearances
2.4 Service pillars
2.4.1 General
2.4.2 Alterations and repairs
2.4.2.1 In Australia
2.4.2.2 In New Zealand
2.4.3 Location
2.4.4 Accessibility
2.4.5 Construction
2.4.5.1 General
2.4.5.2 Height
2.4.5.3 External influences
2.4.5.4 Doors and covers
2.4.5.5 Identification
2.4.5.6 Segregation of wiring systems
2.4.5.7 Strain relief
2.4.6 Socket-outlets
2.4.6.1 General
2.4.6.2 Configuration and rating
2.4.6.3 Marking of socket-outlets
2.4.6.4 Overcurrent protection
2.4.6.5 Protection against earth leakage
2.4.6.6 Control
2.4.6.7 Height of socket-outlets and associated devices
2.4.7 Earthing
2.4.7.1 General earthing arrangements
2.4.7.2 In Australia
2.4.7.3 In New Zealand
2.4.7.3.1 General
2.4.7.3.2 Protective earthing
2.4.7.3.3 Supplementary earthing
2.4.7.4 Earth busbar
3 Supply arrangements to connectable electrical installations at other locations
3.1 General
3.2 Configuration and rating
3.3 Overcurrent protection
3.4 Protection against earth leakage
3.5 Control
3.6 External influences
3.7 Doors and covers
3.8 Strain relief
4 Verification (inspection and testing)
4.1 Initial verification of the installation
4.2 Earth fault-loop impedance
4.3 Periodic assessment (New Zealand only)
Appendix A
A.1 Introduction
A.2 Proposed calculation values
A.2.1 General
A.2.1.1 Camping grounds
A.2.1.2 Caravan parks
A.3 Determination of calculated maximum demand
Appendix B
Appendix C
C.1 Introduction
C.2 Record of Assessment (RoA)
C.3 Inspection of caravan parks
C.3.1 Protection against direct contact
C.3.2 Protection against indirect contact
C.3.3 Wiring systems
C.3.3.1 Underground wiring systems
C.3.3.2 Aerial wiring systems
C.3.4 Service pillars
C.3.4.1 Structural integrity
C.3.4.2 Accessibility
C.3.4.3 Weatherproofing
C.3.4.4 Identification
C.3.4.5 Overcurrent protection
C.3.4.6 Protection against the ingress of moisture
C.3.4.7 Configuration and rating
C.3.4.8 Marking
C.3.4.9 Control
C.3.4.10 Weatherproofing
C.3.4.11 Protection against earth leakage current
C.3.4.12 Strain relief
C.4 General purpose socket-outlets
C.5 Testing of site supplies
C.5.1 Polarity of socket-outlets
C.5.2 Isolating transformers
C.5.3 Earth fault loop impedance
C.6 General-purpose socket-outlets
C.7 Results of assessment
C.7.1 Assessment checklist
C.7.2 Record of assessment
Appendix D
Bibliography
Cited references in this standard
[Current]
Plugs, fixed or portable socket-outlets and appliance inlets for industrial purposes - Part 2: Dimensional compatibility requirements for pin and contact-tube accessories
[Current]
Electrical installations - Verification by inspection and testing
[Current]
Electrical installations - Generating sets
[Current]
Polymeric cable protection covers
Content history
[Superseded]
DR AS/NZS 3001.1:2021

One-time Purchase

Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^

$140.48 AUD

Inclusive of GST
Format *
iconCreated with Sketch.
Web Reader
Licenses *
iconCreated with Sketch.
1 user
Total$140.48 AUD
Add to Cart
IMPORTANT