Standard
Track updates
iconCreated with Sketch.

AS/NZS 2293.2:2019

[Current]

Emergency lighting and exit signs for buildings, Part 2: Routine service and maintenance

Specifies requirements for the periodic inspection and maintenance procedures for emergency evacuation lighting systems to ensure that such lighting systems will be in a state of readiness for operation at all times.
Published: 09/04/2019
Pages: 29
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
1 Scope and general
1.1 Scope
1.2 Application
1.3 Normative references
1.4 Definitions
2 General requirements
2.1 Routine service and maintenance of the installation
2.2 Baseline data of the installation
2.3 Service precautions
2.4 System retrofit
2.5 Frequency and tolerances of routine service intervals
2.5.1 General
2.5.2 Service schedules
2.6 Records and reporting
2.7 Routine service and maintenance records
2.7.1 General
2.7.2 Format of records
2.7.3 Required information
2.7.4 Record retention
2.8 Critical defects
2.8.1 General
2.8.2 Yearly condition report
2.9 Relationships and this standard
3 Inspection, survey, test, service and maintenance procedures
3.1 General
3.2 Required procedures
3.3 Self-contained emergency luminaire and exit sign systems
3.3.1 General
3.3.2 Battery replacement
3.3.3 Replacement of an emergency luminaire or exit sign
3.4 Central battery emergency luminaire and exit sign systems
3.4.1 General
3.4.2 Battery replacement—Central systems
3.5 LED luminaires and exit signs
3.5.1 General
3.5.2 Procedures for end of light source life (LSL) of maintained LED luminaires and exit signs
3.5.2.1 General
3.5.2.2 End of LSL–LED luminaires
3.5.2.3 End of LSL–LED exit signs
3.5.2.4 Measurement
3.5.2.5 Luminaire or dual function exit sign conformance
3.5.2.6 Exit sign conformance
Appendix A
A1 General
A2 Six-monthly requirements
A3 Yearly requirements
A4 10 yearly and end of light source life requirements
Appendix B
B1 Checking of electrolyte level
B2 Battery float-voltage limits
B3 Cell float-voltages/electrolyte density
B4 Neutralizing spilt battery liquid
Appendix C
Appendix D
Appendix E
Appendix F
Appendix G
Bibliography
Cited references in this standard
[Current]
Safety requirements for secondary batteries and battery installations - Part 1: General safety information
[Current]
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
[Current]
Emergency lighting and exit signs for buildings, Part 3: Emergency luminaires and exit signs
[Current]
Emergency lighting and exit signs for buildings, Part 1: System design, installation and operation
[Current]
Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings, Part 2: Sealed cells
Content history
[Superseded]
DR AS/NZS 2293.2:2018

One-time Purchase

Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^

$141.91 AUD

Inclusive of GST
Format *
iconCreated with Sketch.
Web Reader
Licenses *
iconCreated with Sketch.
1 user
Total$141.91 AUD
Add to Cart
IMPORTANT