Specifies the design and test requirements for bolted explosion-protected three-phase cable coupling devices and adaptors of the pin and socket type, referred to in This Standard as ‘cable coupling devices’, for use with restricted earth-fault systems in mines and quarries. The devices are designed to couple cables together, or to couple a cable to equipment.
Published: 09/12/2009
Pages: 26
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
1 Scope and general
1.1 Scope
1.2 Referenced documents
1.3 Definitions
1.4 Service conditions
1.5 Ratings, dimensions and colour coding
1.5.1 Type A
1.5.2 Type B
1.6 Marking
2 Design
2.1 Enclosure
2.1.1 Explosion protection
2.1.2 Ingress protection
2.1.3 Adaptor mounting
2.2 Clearance and creepage distances
2.3 Materials
2.4 Fasteners
2.5 Cable glands
2.6 Terminals
2.6.1 General
2.6.2 Conductor insertion depth
2.7 Contact sockets and pins
2.7.1 Materials
2.7.2 Construction of sockets
2.7.3 Location of sockets and pins
2.7.4 Pins
2.8 Earthing
2.8.1 General
2.8.2 Phase barrier
2.8.3 Terminals
2.9 Phase barrier
2.10 Insulation
2.10.1 Material properties
2.10.2 Thermal endurance
3 Testing
3.1 Categories of tests
3.2 Routine tests
3.2.1 General
3.2.2 High voltage test
3.2.3 Contact pressure test
3.3 Type tests
3.3.1 General
3.3.2 List of type tests
3.3.3 Cable gland (slip load) test
3.3.4 Phase barrier (slip load) test
3.3.5 Thermal endurance test
3.3.6 High voltage test
3.3.7 Contact integrity test
3.3.7.1 Procedure
3.3.7.2 Requirements
3.3.8 Temperature-rise test
3.3.8.1 General
3.3.8.2 Preparation of adaptor
3.3.8.3 Preparation of coupler
3.3.8.4 Placement of temperature-sensing devices
3.3.8.5 Application of current
3.3.8.6 Requirements
3.3.9 Short-circuit (through-fault) tests
3.3.10 Earth-circuit (through-fault) test
3.3.11 Static pressure test
3.3.12 Partial discharge test
3.3.12.1 General
3.3.12.2 Testing procedure
3.3.12.3 Requirements
3.3.13 Impulse withstand test
3.3.13.1 General
3.3.13.2 Testing procedure
3.3.13.3 Requirements
4 Figures and dimensions
4.1 General
4.2 Adaptor, coupler and end cover
4.3 Adaptor mounting template
Appendix A
Appendix B
Appendix C
Amendment control sheet
AS/NZS 1300:2009
Amendment No. 1 (2012)
Correction
Cited references in this standard
[Current]
Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)
AS/NZS 3008.1
Electrical installations—Selection of cables, Part 1: Cables for alternating voltages up to and including 0.6/1 kV (Series)
[Available Superseded]
Explosive atmospheres, Part 0: Equipment — General requirements
[Current]
Explosive atmospheres, Part 1: Equipment protection by flameproof enclosures ‘d’
[Current]
Explosive atmospheres, Part 7: Equipment protection by increased safety “e”
Content history
[Current]
[Superseded]
DR 09021
AS/NZS 1300:2009 REC:2020

One-time Purchase

Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^

$95.34 AUD

Inclusive of GST
Format *
iconCreated with Sketch.
Web Reader
Licenses *
iconCreated with Sketch.
1 user
Total$95.34 AUD
Add to Cart
IMPORTANT