Specifies requirements for PVC-U pipes and fittings for sewer, drain, waste and vent applications above ground or below ground and is intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. The Standard includes requirements for both plain and structured wall pipes and fittings.
Published: 16/06/2009
Pages: 56
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
1 Scope and general
1.1 Scope
1.2 Application
1.3 Normative references
1.4 Definitions
1.5 Ring bending stiffness
1.6 Notation
1.7 Classification
2 General requirements
2.1 General
2.2 Composition
2.3 Colour
2.4 Freedom from defects
2.4.1 General
2.4.2 Spigot ends
2.5 Requirements for elastomeric seals
2.6 Solvent cements
2.7 Packaging, storage and transportation
2.8 Additional requirements for best environmental practice PVC pipes and fittings
3 Performance requirements
3.1 General
3.2 Tests on pipes
3.2.1 Pipe impact characteristics at 20°C
3.2.2 Reversion (for plain wall pipes only)
3.2.3 Bond strength (for hollow profile wall pipes only)
3.2.4 Pipe stiffness
3.2.5 Ring flexibility test (for structured wall pipes only)
3.2.6 Softening temperature (Vicat test)
3.2.7 Elevated temperature cycling test on structured wall pipes (applicable up to and including size DN 80)
3.3 Tests on moulded and fabricated fittings
3.3.1 Hydrostatic pressure test (applicable only to fittings with inspection or access openings and to fabricated fittings)
3.3.2 Hydrostatic pressure test (applicable to pan connectors)
3.3.3 Liquid infiltration test (applicable only to fittings with inspection or test openings)
3.3.4 High temperature stress relief test (applicable only to injection-moulded fittings)
3.3.5 Softening temperature (Vicat test)
3.3.6 Stiffness (for structured and hollow profile wall fittings only)
3.3.7 Elevated temperature cycling test on structured wall fittings (applicable up to and including size DN 80)
3.4 Tests on elastomeric seal joints
3.4.1 General
3.4.2 Hydrostatic pressure test
3.4.3 Liquid infiltration test
3.4.4 Contact width and pressure
3.5 Additional tests on pipe and fittings containing recycled unplasticized PVC
3.5.1 Flattening test
3.5.2 Pipe high temperature test (not applicable to intermediate layers of pipes of sandwich construction)
4 Pipes
4.1 General
4.2 Diameter and wall thickness
4.3 Length
4.4 Pipe spigot ends
4.5 Sockets formed on pipe ends
4.6 Marking
4.7 Witness mark
5 Moulded fittings
5.1 General
5.2 Dimensions of moulded fittings
5.2.1 General
5.2.2 Spigot ends
5.2.3 Sockets on moulded fittings
5.2.4 Tapered spigot ends for solvent cement jointing
5.3 Wall thickness
5.4 Geometry of fittings
5.4.1 Clear bore
5.4.2 Sweep junctions and bends
5.4.3 Eccentric tapers
5.4.4 Gullies
5.4.4.1 Disconnector gullies
5.4.4.2 Floor waste gullies
5.4.5 Vented bends
5.4.6 Pan connectors
5.4.6.1 Outlet
5.4.6.2 Inlet
5.4.6.3 Angle
5.5 Threaded end connections
5.6 Test openings
5.6.1 General
5.6.2 Doors or insert plugs
5.6.3 Threaded caps
5.7 Access openings
5.8 Gratings
5.9 Bolted trap screws
5.10 Overflow relief gratings
5.10.1 Outlet
5.10.2 Inlet
5.11 Marking
6 Fabricated fittings
6.1 General
6.2 Materials
6.3 Compliance
6.4 Marking
7 Elastomeric seal joints
7.1 General
7.2 Design
7.3 Effective sealing length
Appendix A
A1 Scope
A2 Relevance
A3 Batch
A3.1 Acceptable quality level (AQL)
A3.2 Batch
A3.2.1 Material or compound batch
A3.2.2 Pipes or fittings batch
A3.3 Batch release test
A3.4 Inspection level
A3.5 Lot
A3.6 New formulation
A3.7 Process verification test (PVT)
A3.8 Sample
A3.9 Sampling plan
A3.10 Type test (TT)
A4 Product certification
A5 Minimum sampling and testing frequency plan
A5.1 General
A5.2 Retesting
A5.3 Rejection after test
A6 New formulation
Appendix B
Appendix C
C1 Scope
C2 ‘Text deleted’
C3 Requirements
C3.1 Manufacture of PVC resin
C3.1.1 General
C3.1.2 Chlorine
C3.1.3 Vinyl Chloride Monomer (VCM)
C3.1.4 Ethylene Dichloride (EDC) and VCM
C3.1.5 PVC resin
C3.1.6 Environmental management system
C3.2 Manufacture and end of life management of PVC products
C3.2.1 General
C3.2.2 Stabilizers
C3.2.3 Plasticizers
C3.2.4 ‘Text deleted’
C3.3 Use of PVC recyclate in PVC products
C4 Product certification certificate
Amendment control sheet
Bibliography (Informative)
Cited references in this standard
AS/NZS 1426.11
Methods of test for plastics pipes and fittings, Method 11: Method for high temperature stress-relief testing of fittings
NZS 7702
Specification for colours for identification, coding and special purposes
[Current]
PVC pipes and fittings for pressure applications
[Current]
Installation of PVC pipe systems
[Current]
Plumbing and drainage, Part 0: Glossary of terms
Content history
[Available Superseded]
[Available Superseded]
[Superseded]
DR 08216
$193.66
AUD
Inclusive of GST
Available formats
iconCreated with Sketch.
Available formats
icon_export/16/closeCreated with Sketch.
Web Reader
Instantly view standards in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader (PDF)
View standards in PDF format in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader
Licence:
1 user
Total
$193.66
Add to cart
visa logo
mastercard logo
amex logo