Standard
Track updates
iconCreated with Sketch.

AS/NZS 1158.5:2014

[Current]

Lighting for roads and public spaces, Part 5: Tunnels and underpasses

Specifies performance and design requirements for lighting schemes for tunnels and underpasses. It also specifies the luminaire data and other design data that is needed to facilitate the lighting design and the assessment of compliance with the requirements of this Standard.
Published: 14/11/2014
Pages: 49
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
1 Scope and general
1.1 Scope
1.2 Application
1.3 Referenced documents
1.4 Definitions
1.5 Symbols and abbreviations
2 Objectives and light technical parameters
2.1 Road element classification
2.2 General objective
2.3 Design objectives
2.3.1 Principal objectives
2.3.2 Other considerations
2.4 Lighting categories and their application
2.5 Light technical parameters
2.5.1 General
2.5.2 Applicable parameters
2.6 Design lamp lumen value
2.7 Colour rendering
2.8 Energy audit
2.9 Maintenance of light technical parameters
2.9.1 General
2.9.2 Maintenance factor
2.10 Basis of compliance
2.10.1 Compliance of the design
2.10.2 Compliance of the installation
2.11 Determination of stopping sight distance (SSD)
3 Design objectives and light technical parameters
3.1 General
3.2 Tunnel lighting categories
3.3 Lighting of the tunnel zones
3.3.1 Access zone luminance
3.3.2 Threshold zone luminance
3.3.3 Transition zone
3.3.4 Interior zone
3.3.5 Exit zone
3.3.6 Luminance and uniformity values
3.3.6.1 Road surface
3.3.6.2 Tunnel walls
3.3.6.3 Daylight screens
3.3.6.4 Merges and diverges in tunnels
3.3.6.5 Glare control
3.3.7 Control of flicker effect
3.3.8 Controlling of tunnel lighting to accommodate changing ambient lighting
3.3.9 Night-time lighting
3.3.9.1 Tunnel interiors
3.3.9.2 Night time lighting in second interior zone
3.3.9.3 Tunnel exteriors
4 Design of lighting schemes for underpasses
4.1 General
4.2 Underpass lighting categories
4.3 Lighting of underpasses
4.3.1 General
4.3.2 Determination of STP
4.3.3 Lighting Category TU3
4.3.4 Lighting Category TU4
4.3.5 Lighting Category TU5
4.3.6 Underpasses formed by twin bridges
4.3.7 Night-time lighting
4.3.8 Underpasses within Category P roads
5 Electricity supply, other lighting requirements and signage
5.1 Mains failure lighting
5.1.1 General
5.1.2 Category TU1—Long tunnels
5.1.3 Category TU2—Short tunnels
5.1.4 Category TU3—Underpasses with STP < 20%
5.1.5 Category TU4—Underpasses with 20% ≤ STP ≤ 80%
5.1.6 Category TU5—Underpasses with STP > 80%
5.1.7 Duplicate power supplies requirements
5.1.8 Mains power failure lighting requirements
5.2 Emergency lighting and exit signs for escape passages
5.3 Tunnel signage
Appendix A
Appendix B
Appendix C
C1 Driver perceptions
C1.1 On approach to the tunnel
C1.2 Within the tunnel
C2 Tunnel design
C2.1 General
C2.2 On approach to the tunnel
C2.3 Within the tunnel
Appendix D
D1 Assessment of the see-through percentage
D1.1 Preparation of a representation of the underpass
D1.2 Determination of the see-through percentage
D1.2.1 Projected surface method
D1.2.2 Viewing angle method
D2 Specific situation analysis for determination of need for daytime lighting for lighting—Category TU4
D2.1 Preparation of a representation of the underpass and critical object
D2.2 Determination of the visibility of the critical object
D2.3 Daylight contribution to lighting within the underpass.
Appendix E
E1 Methodology
E1.1 General
E1.2 The luminance step method
E1.3 The luminance reduction curve method
E2 Light technical parameters
E2.1 Formulae
E2.2 Threshold increment
E2.3 Uniformity
E3 Designated calculation fields
E3.1 Road surface
E3.1.1 Road surface calculation field
E3.1.2 Road surface calculation points
E3.2 Wall surface
E3.2.1 Wall surface calculation field
E3.2.2 Wall surface calculation points
E3.2.3 Inter-reflected light
E3.3 Observer position
E3.4 Luminaire contributions
E4 Photometric data
E4.1 Luminaire light distribution
E4.2 Luminaire data format
E4.3 Rounding of calculated values
E5 Road surfaces
E5.1 Standard road surfaces
E5.2 Other surfaces
Appendix F
F1 General
F2 Luminaire maintenance factor
F3 Lamp lumen depreciation factor
F4 Maintenance factor
F5 Maintenance program
F6 Maintenance of wall luminance
Appendix G
Appendix H
Appendix I
I1 General
I2 Site plans
I3 Lighting scheme performance requirements
I4 Specific requirements
Appendix J
J1 Mandatory requirements
J2 Additional requirements where audit is requested
Appendix K
Appendix L
Cited references in this standard
[Withdrawn]
Lighting system performance — Accuracies and tolerances, Part 2: Compliance requirements
AS/NZS 132
Design methods for lighting of roads
[Withdrawn]
Lighting system performance — Accuracies and tolerances, Part 1: Overview and general recommendations
[Current]
Interior lighting, Part 0: Safe movement
[Available Superseded]
Lighting for roads and public spaces, Part 6: Luminaires
Content history
[Available Superseded]
[Available Superseded]
DR AS/NZS 1158.5
$193.66
AUD
Inclusive of GST
Available formats
iconCreated with Sketch.
Available formats
icon_export/16/closeCreated with Sketch.
Web Reader
Instantly view standards in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader (PDF)
View standards in PDF format in your browser. Search, bookmark, highlight, and comment for anytime access - online and offline.
Web Reader
Licence:
1 user
Total
$193.66
Add to cart
visa logo
mastercard logo
amex logo