Standard
Track updates
AS 4654.1-2012
[Pending Revision]Waterproofing membranes for external above-ground use, Part 1: Materials
Sets out requirements for waterproofing membranes for external above-ground use, installed in accordance with AS 4654.2.
Published: 14/09/2012
Pages: 14
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
1.1 Scope
1.2 Normative references
1.3 Definitions
1.4 Membrane systems
1.5 Exposed and protected systems
2 Testing
2.1 Scope of section
2.2 Conformance conditions
2.3 Abrasion resistance
2.3.1 Non-trafficable
2.3.2 Trafficable
2.4 Bond strength to substrate
2.5 Field seam strength
2.6 Temperature resistance
2.7 Resistance to ultraviolet light
2.8 Bioresistance of membranes
2.9 Root resistance
Appendix A
A1 General
A2 Classification
A3 Joint movement accommodation
A4 Properties of membranes
A4.1 Basic properties
A4.2 Durability of membranes
A4.2.1 General
A4.2.2 Preparation and testing of specimens
A4.2.2.1 Preparation
A4.2.2.2 Testing
Appendix B
B1 Scope
B2 Test method
B2.1 Preparation of specimen
B2.2 Test
B2.3 Measurement criteria
B3 Reporting of results
B4 Test pass or fail
Bibliography
Cited references in this standard
BS EN 12691
Flexible sheets for waterproofing. Bitumen, plastic and rubber sheets for roof waterproofing. Determination of resistance to impact
BS EN12310-1
Flexible sheets for waterproofing. Determination of resistance to tearing (nail shank), Part 1: Bitumen sheets for roof waterproofing
ASTM E96
Standard Test Methods for Water Vapor Transmission of Materials
ASTM D6207
Standard Test Method for Dimensional Stability of Fabrics to Changes in Humidity and Temperature
ASTM D5602
Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens