Standard
Track updates
AS 2796.1-1999
[Current]Timber — Hardwood — Sawn and milled products, Part 1: Product specification
Specifies product requirements for sawn and milled hardwood products. Moisture content, profiles, tolerances and grades are covered. Requirements are also given for glued laminating, finger jointing and end-matching. Guidance is given on information to be supplied when ordering.
Published: 05/09/1999
Pages: 39
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
PREFACE
1 SCOPE AND GENERAL
1.1 SCOPE
1.2 APPLICATION
1.3 REFERENCED DOCUMENTS
1.4 DEFINITIONS
1.5 GRADES
1.6 PRODUCT IDENTIFICATION
1.7 CLAIM OF COMPLIANCE
2 GENERAL REQUIREMENTS
2.1 TIMBER SPECIES
2.2 MOISTURE CONTENT AND DRYING QUALITY
2.3 SAPWOOD AND LOW DURABILITY HEARTWOOD
2.4 SAPWOOD SUSCEPTIBLE TO LYCTID BORERS
2.5 PRESERVATIVE TREATMENT
2.6 MEASUREMENT OF DIMENSIONS AND DISTORTIONS
2.6.1 Dimensions
2.6.2 Bow and spring
2.6.3 Twist
2.6.4 Cup
2.7 TIMBER SURFACES
2.7.1 Types
2.7.2 Machining imperfections and surface finish imperfections
2.8 FINGER JOINTED PRODUCTS
2.9 GLUED LAMINATED PRODUCTS
2.10 END-MATCHED PRODUCTS
3 STRIP FLOORING
3.1 GENERAL
3.2 MOISTURE CONTENT
3.3 PROFILES
3.4 TOLERANCES
3.5 GRADE
4 LIGHT DECKING
4.1 GENERAL
4.2 MOISTURE CONTENT
4.3 PROFILES
4.4 TOLERANCES
4.5 GRADE
5 PARQUET FLOORING
5.1 GENERAL
5.2 MOISTURE CONTENT
5.3 PROFILES
5.3.1 Wood blocks
5.3.2 Mosaic fingers
5.4 TOLERANCES
5.5 GRADE
6 LINING BOARDS
6.1 GENERAL
6.2 MOISTURE CONTENT
6.3 PROFILES
6.4 TOLERANCES
6.5 GRADE
7 DRESSED BOARDS, JOINERY AND MOULDINGS
7.1 GENERAL
7.2 MOISTURE CONTENT
7.3 PROFILES
7.4 TOLERANCES
7.5 GRADE
8 CLADDING, FASCIA AND BARGEBOARDS
8.1 GENERAL
8.2 MOISTURE CONTENT
8.3 PROFILES
8.3.1 General
8.3.2 Rebate or overlap of cladding fixed horizontally
8.3.3 Rebate or overlap of cladding fixed other than horizontally
8.4 TOLERANCES
8.5 GRADE
9 SAWN BOARDS FOR FEEDSTOCK (DRESSING)
9.1 GENERAL
9.2 MOISTURE CONTENT
9.3 TOLERANCES
9.4 GRADE
10 OVERLAY STRIP FLOORING
10.1 GENERAL
10.2 MOISTURE CONTENT
10.3 PROFILES
10.4 TOLERANCES
10.5 GRADE
APPENDIX A
APPENDIX B
APPENDIX C
APPENDIX D
APPENDIX E
APPENDIX F
F1 SCOPE
F2 FINGER JOINT CONFIGURATION
F3 FINGER JOINTING REQUIREMENTS
APPENDIX G
G1 SCOPE
G2 LAMINATING CONFIGURATION
G3 GLUE LAMINATING REQUIREMENTS
APPENDIX H
H1 SCOPE
H2 TONGUES AND GROOVES
H3 END MATCHING ORIENTATION
Cited references in this standard
[Current]
Residential timber-framed construction — AS 1684.2 (Non-cyclone areas) & AS 1684.3 (Cyclone areas) Supplements
Content history
[Superseded]
[Superseded]
[Superseded]
[Superseded]
[Withdrawn]
One-time Purchase
Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^
$141.91 AUD
Inclusive of GSTFormat *
Web Reader
Licenses *
1 user
Total$141.91 AUD
IMPORTANT