1 Scope and general
1.1 Scope
1.2 Application
1.3 Referenced documents
1.4 Definitions
2 General requirements
2.1 Introduction
2.2 General requirements
2.2.1 Portable appliances
2.2.2 Mobile appliances
2.3 Components
2.3.1 Certification of safety components
2.3.2 Limitation of gas flow
2.3.3 Holes for screws, pins, etc
2.3.4 Metal-to-metal joint or joints
2.3.5 Removable components
2.3.6 Soft solder
2.3.7 Flame supervision devices
2.4 Mechanical design
2.4.1 Stability
2.4.2 Displacement of parts
2.4.3 Gas containers and associated flexible hose assemblies
2.4.4 Appliances connected to the gas container by a flexible hose assembly
2.4.5 Appliances connected directly to the gas container
2.4.6 Appliances connected directly to a disposable cartridge
2.4.7 Appliances directly fitted to a pierceable gas cartridge
2.4.8 Locations and compartments for gas containers
2.4.8.1 Compartments for gas containers
2.4.8.2 Location for a gas container
2.4.9 Burners and radiant elements
2.4.10 Unburnt gas release from burner system
2.4.11 Burner mixing tubes
2.4.12 Gas manifolds
2.4.13 Flash lighting systems and cross lighting devices
2.4.13.1 Flash lighting tubes
2.4.13.2 Cross lighting devices
2.4.14 Jointing
2.4.15 Utensil supports
2.4.16 Cooking grids
2.4.16.1 General
2.4.16.2 Grid with a rigid useful area
2.4.17 User adjustment for different gases
2.5 Materials and finishes
2.5.1 Suitability of materials and finishes
2.5.2 Materials containing asbestos
2.5.3 Materials in contact with gas
2.5.4 Materials in contact with food
2.5.5 Copper tubing
2.5.6 Brass tubing and fittings
2.5.7 Die-casting
2.6 Gas connections
2.6.1 Connection to appliance and container
2.6.2 Appliance connections to non-refillable containers
2.7 Design for use
2.7.1 Assembly
2.7.2 Prevention of incorrect assembly
2.7.3 Accessibility of controls and working parts
2.7.4 Viewing of burner flames
2.7.5 Control valve
2.7.5.1 General
2.7.5.2 Needle valves
2.7.6 Gas control
2.7.7 Accumulation of unburnt gas
2.7.8 Adjusting devices
2.7.9 Wheels
2.7.10 Gas systems—Resistance to displacement
2.8 Prevention of injury during ignition
2.9 Design for maintenance (general)
2.9.1 Sharp edges
2.9.2 Injectors
2.9.3 Dismantling and replacement by user
2.9.4 Cleaning, maintenance and removability of parts by an authorised person
2.10 Gas leakage
2.10.1 Gas tightness
2.10.2 Gas tightness after testing
2.10.3 Needle valves—Gas tightness
2.11 Nominal gas consumption
2.11.1 General
2.11.2 Tolerance on determined gas consumption
2.12 Temperature hazards
2.12.1 Test conditions
2.12.2 Floor, wall, overhead and bench surfaces
2.12.3 Surfaces intended to be handled
2.12.4 Temperatures of surfaces likely to be accidentally touched
2.12.5 Temperatures of components
2.12.5.1 Bodies of gas valves, thermostats, etc
2.12.5.2 Components containing non-metallic diaphragms
2.12.5.3 Flexible hoses
2.12.5.4 Joints sealed with jointing materials
2.12.5.5 Glass components
2.12.5.6 Gas container
2.12.6 Gas container safety at high temperature
2.12.7 Gas container safety at overload gas consumption
2.13 Heat resistance
2.13.1 General
2.13.2 Normal operation
2.13.3 Light-back operation
2.14 Burner operation
2.14.1 Ignition device
2.14.2 Ignition
2.14.3 Delayed ignition
2.14.4 ‘Text deleted’
2.14.5 Burner stability when changing setting
2.14.6 Flame stability to draught
2.14.7 Flame characteristics maximum and minimum limiting conditions
2.15 Combustion tests
2.15.1 General
2.15.2 Appliances other than heaters and lamps
2.15.3 Heaters and lamps
2.15.4 Appliances fitted with surface combustion burners
2.15.5 Sooting
2.15.6 Condensation
2.16 Instructions and marking
2.16.1 Instructions supplied with appliance
2.16.1.1 General
2.16.1.2 Information about the appliance
2.16.1.3 Safety information, abnormal operation, maintenance schedule, service and replacement parts
2.16.1.4 Information for use
2.16.1.5 Information for appliances with pierceable cartridges
2.16.2 Assembly
2.16.3 Appliance markings
2.16.4 Marking of control valves
2.16.4.1 Plug type control valves
2.16.4.2 Needle valves
2.16.5 Durability of permanent markings
2.16.6 Markings on packaging
2.17 Specifications
2.17.1 Preliminary specification
2.17.2 Provision of specifications
3 Additional requirements for cookers
3.1 Hotplate burners on cookers
3.1.1 Turndown control
3.1.2 Ignition
3.1.3 Flame characteristics
3.1.4 Resistance to liquid spillage
3.1.5 Pan stability
3.1.6 Pan supports
3.2 Ovens
3.2.1 Flame safeguards for cooker ovens
3.2.2 Shelves
3.2.3 Shelf supports
3.2.4 Fitting of thermostat
3.3 Strength—Applied load
3.4 Combustion
3.5 Temperature hazards
3.6 Heat resistance
3.7 Additional requirements for cookers with enclosed gas cartridges
3.7.1 Overpressure protection
3.7.2 Instructions
3.7.3 Markings
3.7.3.1 General
3.7.3.2 Pan support—marking
3.7.4 Temperature hazards
3.7.5 Cartridge—Maximum pressure
3.7.6 Durability
3.7.6.1 General
3.7.6.2 Gas valve
3.7.6.3 Appliance regulator
3.7.6.4 Overpressure shut off device
3.7.6.5 Cartridge to valve connection
3.7.7 Cartridge—Installation integrity
3.7.8 Retaining springs for cartridge retention mechanism
3.7.9 Protection of cartridge retention and overpressure safety system mechanisms
3.7.10 Drop test
4 Additional requirements for heaters
4.1 Application of this section
4.2 Enclosed fuel storage
4.3 Marking
4.4 Flame safeguards
4.5 Vitiation
4.5.1 Operation in a sealed test chamber—All heaters
4.5.2 Operation in a sealed test chamber—Heaters with gas consumption in excess of 6MJ/h
4.6 Primary guard
4.6.1 General
4.6.2 Attachment to the appliance
4.6.3 Openings in a primary guard
4.6.4 Cone test
4.6.5 Smoulder test
4.6.6 Glass components
4.6.7 Exposed surfaces
4.6.8 Primary guard temperature
4.7 Temperature hazards
4.8 Heat resistance
4.9 Additional requirements for heaters with enclosed gas cartridge
4.9.1 Overpressure protection
4.9.2 Tip over switch
4.9.3 Durability
4.9.3.1 General
4.9.4 Cartridge-installation integrity
4.9.5 Retaining springs for cartridges retention mechanism
4.9.6 Protection of cartridge retention and overpressure safety system mechanisms
4.10 Drop test
5 Additional requirements for barbecues
5.1 Marking
5.2 Combustion
5.3 Temperature hazards
5.3.1 General
5.3.2 Hood handles
5.3.3 Grease receptacle
5.4 Heat resistance
5.5 Mechanical design
5.5.1 Provision and location of grease receptacle
5.5.2 Design to prevent ignition of accumulated grease
5.5.3 Protection of ports and injectors
5.5.4 Glass components—Resistance to mechanical shock
5.5.5 Glass components—Resistance to thermal shock
6 Additional requirements for gaslights
6.1 Markings
6.2 Durability
6.3 Mantles
7 Requirements for hand-held heating tools
7.1 General
7.2 Markings
7.2.1 General
7.2.2 Markings on packaging of hand-held heating tools
7.3 Gas flow control
7.4 Storage case or container
7.5 Cleaning, maintenance and removability of parts designed to be replaced
7.6 Temperature hazards
7.7 Heat resistance
7.8 Flame generation
7.9 Device to prevent inadvertent operation
7.10 Gas to be turned off when control is released
7.11 Resistance to spitting or sputtering and flaring
7.12 Burning behaviour
7.12.1 Burners—Light-back condition
7.12.2 Flaring, burning and distortion
7.13 Accelerated ageing test
7.14 Refillable containers
7.15 Pressure test—Tools with integral container
7.16 Drop test
8 Portable water heaters for outdoor use
8.1 Materials
8.2 Stability
8.3 Restrictions of openings in appliance
8.4 Safety shut off system
8.5 Thermostats
8.6 Automatic gas shut off systems
8.6.1 Provision of automatic gas shut off system
8.6.2 Type of automatic gas shut off system
8.6.3 Surface mounted automatic shut off devices
8.6.4 Accessibility
8.7 Pressure relief
8.7.1 Relief valves—Unvented appliances containing more than one litre of water
8.7.2 Relief device—Unvented water heaters containing not more than one litre of water
8.8 Combustion
8.8.1 Combustion at high setting
8.8.2 Restricted flue outlet
8.9 Temperature control
8.9.1 Outlet water temperature
8.9.2 Heat exchanger temperature
8.10 Requirements for automatic ignition or reignition systems
8.11 Wind test
8.11.1 Main burner ignition under wind conditions
8.11.2 Combustion under wind conditions
8.12 Hydrostatic strength
8.13 Rain and shower resistance
8.13.1 Operation after and during simulated rainstorm
8.13.2 Operation during spraying with a shower rose
8.14 Markings and instructions
8.14.1 Appliances not intended for the supply of drinking water
8.14.2 Warning related to water temperature
8.14.3 Unvented appliances
8.14.4 Warning labels
8.15 Temperature hazards
8.16 Heat resistance
9 Preparation for testing
9.1 Preparation for testing
9.1.1 Test gases
9.1.1.1 General
9.1.1.2 Appliances operating from a cylinder or refillable container
9.1.1.3 Appliances operating from a non-refillable container
9.1.2 Test gases used for temperature hazard and heat resistance tests
9.2 Setting up appliance for testing
9.2.1 Appliance set up
9.2.2 Test conditions—Appliances intended for use with non-refillable containers
9.2.3 Test pressures—Appliances intended for use with refillable containers
9.2.4 Appliances supplied with gas from a refillable container and using a regulator
9.2.5 Appliance regulators
9.2.6 Draughts
9.2.7 Variable restrictors
Appendix A
Appendix B
B1 M.O.T. 2.3.7(d)—Ignition—Opening of flame safeguard system
B1.1 Scope
B1.2 Principle
B1.3 Apparatus
B1.4 Materials
B1.5 Preparation of apparatus
B1.6 Procedure
B1.7 Result
B2 M.O.T. 2.3.7(e)—Operation of safety shut off system
B2.1 Scope
B2.2 Principle
B2.3 Materials
B2.4 Apparatus
B2.5 Preparation of apparatus
B2.6 Procedure
B2.7 Result
B3 M.O.T. 2.4.1—Stability test for freestanding appliances
B3.1 Scope
B3.2 Principle
B3.3 Apparatus
B3.4 Preparation of apparatus
B3.5 Procedure
B3.6 Result
B4 M.O.T. 2.4.10—Burner operation—Unburnt gas release from burner system
B4.1 Scope
B4.2 Principle
B4.3 Apparatus
B4.4 Materials
B4.5 Preparation of apparatus
B4.6 Procedure
B4.7 Result
B5 M.O.T. 2.5.7—Zinc alloy
B5.1 Scope
B5.2 Principle
B5.3 Apparatus
B5.4 Procedure
B5.5 Result
B6 M.O.T. 2.7.10—Displacement test
B6.1 Scope
B6.2 Principle
B6.3 Materials
B6.4 Preparation of apparatus
B6.5 Procedure
B6.6 Result
B7 M.O.T. 2.10.1—Gas leakage—Fully assembled appliances
B7.1 Scope
B7.2 Principle
B7.3 Apparatus
B7.4 Materials
B7.5 Preparation of apparatus
B7.6 Procedure
B7.6.1 Procedure for unregulated parts of appliances
B7.6.2 Procedure for regulated parts of appliances
B7.7 Result
B8 M.O.T. 2.10.3(a)—Needle valves—Resistance to temperature
B8.1 Scope
B8.2 Principle
B8.3 Apparatus
B8.4 Materials
B8.5 Preparation of apparatus
B8.6 Procedure
B8.7 Result
B9 M.O.T. 2.10.3(b)—Needle valves—Durability
B9.1 Scope
B9.2 Principle
B9.3 Apparatus
B9.4 Materials
B9.5 Preparation of apparatus
B9.6 Procedure
B9.7 Result
B10 M.O.T. 2.11.1—Gas consumption test
B10.1 Scope
B10.2 Principle
B10.3 Apparatus
B10.4 Materials
B10.5 Preparation of apparatus
B10.6 Procedure
B10.7 Result
B11 M.O.T. 2.12—Temperature hazards
B11.1 Scope
B11.2 Principle
B11.3 Apparatus
B11.3.1 All appliances
B11.3.2 Additional apparatus for cookers
B11.3.3 Additional apparatus for heaters
B11.3.4 Additional apparatus for barbecues
B11.4 Materials
B11.4.1 All appliances
B11.4.2 Additional materials for cookers and barbecues and water heaters
B11.5 Preparation of apparatus
B11.5.1 All appliances
B11.5.2 Additional preparation for barbecues
B11.6 Procedure—Cookers
B11.7 Procedure—Heaters
B11.8 Procedure—Barbecues
B11.9 Procedure—Gas lights, hand-held heating tools and miscellaneous appliances
B11.10 Procedure—Water heaters
B11.11 Result
B12 M.O.T. 2.12.6—Non-refillable container safety
B12.1 Scope
B12.2 Principle
B12.3 Apparatus
B12.4 Materials
B12.5 Preparation of apparatus
B12.6 Procedure
B12.7 Results
B13 M.O.T. 2.13.2—Heat resistance
B13.1 Scope
B13.2 Principle
B13.3 Apparatus
B13.3.1 All appliances
B13.3.2 Additional apparatus for cookers
B13.3.3 Additional apparatus for barbecues
B13.4 Materials
B13.4.1 All appliances
B13.4.2 Additional materials for cookers and barbecues and water heaters
B13.5 Preparation of apparatus
B13.5.1 All appliances
B13.5.2 Additional preparation for barbecues
B13.6 Procedure—Cookers
B13.7 Procedure—Heaters
B13.8 Procedure—Barbecues
B13.9 Procedure—Gas lights, hand-held heating tools and miscellaneous appliances
B13.10 Procedure—Water heaters
B13.11 Result
B14 M.O.T. 2.13.3—Heat resistance—Light-back condition
B14.1 Scope
B14.2 Principle
B14.3 Apparatus
B14.4 Materials
B14.5 Preparation of apparatus
B14.6 Procedure
B14.7 Result
B15 M.O.T. 2.14.2—Ignition
B15.1 Scope
B15.2 Principle
B15.3 Apparatus
B15.4 Materials
B15.5 Preparation of apparatus
B15.6 Procedure
B15.7 Result
B16 M.O.T. 2.14.3—Delayed ignition
B16.1 Scope
B16.2 Principle
B16.3 Apparatus
B16.4 Materials
B16.5 Preparation of apparatus
B16.6 Procedure
B16.7 Result
B17 M.O.T. 2.14.6—Flame stability to draught
B17.1 Scope
B17.2 Principle
B17.3 Apparatus
B17.4 Materials
B17.5 Preparation of apparatus
B17.6 Procedure
B17.7 Result
B18 M.O.T. 2.14.7—Flame abnormality
B18.1 Scope
B18.2 Principle
B18.3 Materials
B18.4 Preparation of apparatus
B18.5 Procedure
B18.6 Result
B19 M.O.T. 2.15.2/3—Determination of CO/CO2 ratio in combustion products
B19.1 Scope
B19.2 Principle
B19.3 Apparatus
B19.4 Materials
B19.5 Preparation of apparatus
B19.6 Procedure
B19.7 Result
B20 M.O.T. 2.15.4—Determination of CO/CO2 ratio in combustion products of surface combustion burners
B20.1 Scope
B20.2 Principle
B20.3 Apparatus
B20.4 Materials
B20.5 Preparation of apparatus
B20.6 Procedure
B20.7 Result
B21 M.O.T. 2.16.5—Marking
B21.1 Scope
B21.2 Principle
B21.3 Apparatus
B21.4 Materials
B21.5 Procedure
B21.6 Result
B22 M.O.T. 3.1.4—Spillover
B22.1 Scope
B22.2 Principle
B22.3 Apparatus
B22.4 Materials
B22.5 Preparation of apparatus
B22.6 Procedure
B22.7 Result
B23 M.O.T. 3.1.5—Pan stability test
B23.1 Scope
B23.2 Principle
B23.3 Apparatus
B23.4 Procedure
B23.5 Result
B24 M.O.T. 3.7.10/4.10—Drop test—Cookers and heaters with enclosed gas cartridge
B24.1 Scope
B24.2 Principle
B24.3 Apparatus
B24.4 Procedure
B24.5 Result
B25 M.O.T. 4.5.1—Vitiation
B25.1 Scope
B25.2 Principle
B25.3 Materials
B25.4 Apparatus
B25.5 Preparation of apparatus
B25.6 Procedure
B25.7 Result
B26 M.O.T. 4.5.2—Safety system—Heaters with gas consumption in excess of 6 MJ/h
B26.1 Scope
B26.2 Principle
B26.3 Materials
B26.4 Apparatus
B26.5 Preparation of apparatus
B26.6 Procedure
B26.7 Result
B27 M.O.T. 4.6.2—Integrity of the primary guard
B27.1 Scope
B27.2 Principle
B27.3 Apparatus
B27.4 Preparation of apparatus
B27.5 Procedure
B27.6 Result
B28 M.O.T. 4.6.5—Fabric smoulder test
B28.1 Scope
B28.2 Principle
B28.3 Apparatus
B28.4 Materials
B28.5 Preparation of apparatus
B28.6 Procedure
B28.7 Result
B29 M.O.T. 4.6.6—Resistance of glass components to impact
B29.1 Scope
B29.2 Principle
B29.3 Apparatus
B29.4 Preparation of apparatus
B29.5 Procedure
B29.6 Result
B30 M.O.T. 4.9.2—Heaters—Tip over switch test
B30.1 Scope
B30.2 Principle
B30.3 Apparatus
B30.4 Procedure
B30.5 Result
B31 M.O.T. 5.5.4—Glass components—Resistance to mechanical shock
B31.1 Scope
B31.2 Principle
B31.3 Materials
B31.4 Preparation of apparatus
B31.5 Procedure
B31.6 Result
B32 M.O.T. 5.5.5—Glass components—Resistance to thermal shock
B32.1 Scope
B32.2 Principle
B32.3 Apparatus
B32.4 Materials
B32.5 Preparation of apparatus
B32.6 Procedure
B32.7 Result
B33 M.O.T. 7.11—Resistance to spitting or sputtering and flaring
B33.1 Scope
B33.2 Principle
B33.3 Apparatus
B33.4 Materials
B33.5 Preparation of apparatus
B33.6 Procedure
B33.7 Result
B34 M.O.T. 7.12.2—Burning behaviour
B34.1 Scope
B34.2 Principle
B34.3 Materials
B34.4 Preparation of apparatus
B34.5 Procedure
B34.6 Result
B35 M.O.T. 7.16—Drop test—Hand-held tools
B35.1 Scope
B35.2 Principle
B35.3 Apparatus
B35.4 Procedure
B35.5 Result
B36 M.O.T. 8.7.2—Operation of relief device of unvented water heaters containing less than one litre of water
B36.1 Scope
B36.2 Principle
B36.3 Apparatus
B36.4 Materials
B36.5 Preparation of apparatus
B36.6 Procedure
B36.7 Result
B37 M.O.T. 8.9.1—Outlet water temperature
B37.1 Scope
B37.2 Principle
B37.3 Materials
B37.4 Apparatus
B37.5 Preparation of apparatus
B37.6 Procedure
B37.7 Result
B38 M.O.T. 8.9.2—Maximum heat exchanger temperature
B38.1 Scope
B38.2 Principle
B38.3 Materials
B38.4 Apparatus
B38.5 Preparation of apparatus
B38.6 Procedure
B38.7 Result
B39 M.O.T. 8.11—Wind test
B39.1 Scope
B39.2 Principle
B39.3 Apparatus
B39.4 Materials
B39.5 Preparation of apparatus
B39.6 Procedure
B39.7 Result
B40 M.O.T. 8.12—Hydrostatic strength test
B40.1 Scope
B40.2 Principle
B40.3 Apparatus
B40.4 Materials
B40.5 Preparation of apparatus
B40.6 Procedure
B40.7 Result
B41 M.O.T. 8.13—Rain and shower water resistance
B41.1 Scope
B41.2 Principle
B41.3 Apparatus
B41.4 Materials
B41.5 Preparation of apparatus
B41.6 Procedure
B41.6.1 All appliances
B41.6.2 Additional test for appliances with integral shower
B41.7 Result
Appendix C
Appendix D
Appendix E
Appendix F
Amendment control sheet
AS 2658—2008
Amendment No. 1 (2009)
Revised text
Amendment No. 2 (2011)
Revised text
Amendment No. 3 (2013)
Revised text
Appendix Former Wording
F.1 Purpose of this Appendix
F.2 Former wording texts and notes
F2.1 Former Clause 1.1 item (a) Former Wording
F2.2 Former Clause 1.1 third paragraph Former Wording
F2.3 Former Clause 1.1 Notes 3-7 Former Wording
F2.4 New Clause 1.4.0 New Clause
F2.5 New Clause 1.4.2.4 New Clause
F2.6 New Clause 1.4.10A New Clause
F2.7 Former Clause 1.4.11 Former Wording
F2.8 Former Clause 2.1 last paragraph Former Wording
F2.9 Former Clause 2.4.1 Former Wording
F2.10 Former Clause 2.4.3 Former Wording
F2.11 Former Clause 2.9.2 Former Wording
F2.12 Former Clause 2.11.2 Former Wording
F2.13 Former Clause 2.14 Former heading
F2.14 Former Clause 2.14.2 Former Wording
F2.15 Former Clause 2.14.4 Former Wording
F2.16 New Clause 2.14.5 New paragraph
F2.17 Former Clause 2.16.1.2 Former Wording
F2.18 Former Clause 2.16.3 Former Wording
F2.19 Former Clause 3.1.2 Former Wording
F2.20 Former Clause 3.1.3 Former Wording
F2.21 Former Clause 3.1.4 Former Wording
F2.22 Former Clause 3.1.5 Former Wording
F2.23 New Clause 3.1.6 New Clause
F2.24 Former Clause 3.4 Former Wording
F2.25 Clause 3.5 New item
F2.26 Former Clause 3.7 Former Heading
F2.27 Former Clause 3.7.3.1 Former Wording
F2.28 Former Clause 3.7.7 Former Wording
F2.29 Former Clause 3.7.9 Former Wording
F2.30 Former Clause 3.7.10 Former Wording
F2.31 Former Clause 4.1 Former Wording
F2.32 Former Clause 4.3 Former Wording
F2.33 Former Clause 4.4 first paragraph Former Wording
F2.34 Former heading to Clause 4.9 Former Wording
F2.35 New Clauses 4.9.3, 4.9.4, 4.9.5 and 4.9.6 New Clauses
F2.36 Former Clause 4.10 Former Wording
F2.37 Former Clause 5.1 Former wording
F2.38 Former Clause 7.2.2Former Wording
F2.39 Former Clause 7.3(b) Former Wording
F2.40 Former Clause 7.4 Former Wording
F2.41 Former Clause 7.6 Former Wording
F2.42 Former Clause 7.7 Former Wording
F2.43 Former Clause 8.2 Former Wording
F2.44 Former Clause 8.11.2 Former Wording
F2.45 New Clause 8.14.4 New Clause
F2.46 Former Clause 9.1.1.3 Former Wording
F2.47 Former Clause 9.1.2 Former Wording
F2.48 Former Table 9.1 Former Wording
F2.49 Former Table 9.2(b) Former Wording
F2.50 Former Clause 9.2.5 Former Wording
F2.51 Former Appendix A Former Wording
F2.52 Figure A5 New note
F2.53 Former Paragraph B3.5 Former Wording
F2.54 Paragraph B7.4, New item (b)(iii)
F2.55 Paragraph B7.6.1, New heading
F2.56 Paragraph B7.6.2 New Clause
F2.57 Former Paragraph B10.7 Former Wording
F2.58 Former Paragraph B11.3.2 Former Wording
F2.59 Former Paragraph B10.6 Former Wording
F2.60 Former Paragraph B11.6 Former Wording
F2.61 Former Paragraph B11.11 Former Wording
F2.62 Former heading to Paragraph B12 Former Wording
F2.63 Paragraph B13 Former heading
F2.64 Former Paragraph B13.11 Former Wording
F2.65 Former Paragraph B14 Former Heading
F2.66 Former Paragraph B14.7 Former Wording
F2.67 Former Paragraph B15.2 Former Wording
F2.68 Former Paragraph B15.4 Former Wording
F2.69 Former Paragraph B15.6 Former Wording
F2.70 Former Paragraph B18.4, Former Note
F2.71 New Paragraph B18.5, New item
F2.72 Former Paragraph B19 Former Heading
F2.73 Former Paragraph B19.4 Former Wording
F2.74 Former Paragraph B19.6 Former Wording
F2.75 Former Paragraph B19.7 Former Wording
F2.76 Former Paragraph B20 Former Heading
F2.77 Former Paragraph B23.3 Former Wording
F2.78 Former Paragraph B23.5 Former Wording
F2.79 Former Paragraph B24 Former Heading
F2.80 Former Paragraph B24.1 Former Wording
F2.81 Former heading to Paragraph B24.5 Former Wording
F2.82 Former Paragraph 25.1 Former Wording
F2.83 Former Appendix B, Figure E1 Former Wording
F2.84 Former Appendix F, reference to AS 2278 Former Wording
Cited references in this standard
AS 4551 (AG 101)
Domestic gas cooking appliances
Content history
[Current]
[Superseded]
[Superseded]
[Superseded]
[Superseded]
One-time Purchase
Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^
$282.33 AUD
Inclusive of GSTFormat *
Web Reader
Licenses *
1 user
Total$282.33 AUD
IMPORTANT