AS 2252.2-2009
[Superseded]Specifies basic requirements for Class II laminar flow biological safety cabinets that are intended to provide protection from hazardous biological agents for personnel and the environment and also to protect material use in the cabinet from exogenous contamination. It is intended that this Standard be read in conjunction with AS 2252.4 which describes recommended practices for installation and use of these cabinets.
Published: 02/11/2009
Pages: 15
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
Foreword
1 Scope
2 Referenced documents
3 General requirements
4 Construction requirements
4.1 General
4.2 Outer shell
4.3 Work zone
4.3.1 General
4.3.2 Viewing windows
4.3.3 Work access opening
4.3.4 Work access opening cover
4.3.5 Work zone illumination
4.3.6 Work floor
4.3.7 Grilles
4.3.8 Sump
4.4 Filters and filter installations
4.5 Blowers and alarm systems
4.5.1 Blowers
4.5.2 Blower alarm systems
4.6 Access panels
4.7 Electrical services
4.8 Germicidal ultraviolet (UV) lamps
4.9 Gas supply
4.10 Adsorbent filter
4.11 Post-use overrun control
4.12 Decontamination covers
5 Performance requirements
5.1 General
5.1.1 Factory test requirements
5.1.2 Installation test requirements
5.1.3 Periodic test requirements
5.2 Critical performance tests for cabinet function
5.2.1 Filter installation integrity
5.2.2 Containment at the aperture
5.2.3 Work zone integrity
5.2.4 Air velocity and uniformity in the work zone
5.2.5 Alarm operational adjustment
5.2.6 Gastightness of outer shell
5.3 Tests related to operator comfort and safety
5.3.1 General
5.3.2 Vibration
5.3.3 Sound level
5.3.4 Lighting
5.3.5 Ultraviolet radiation
6 Marking
Appendix A
A1 General
A2 Considerations of ergonomics for safety cabinets and isolators
A2.1 General
A2.2 Design
A2.3 Purchase and use
Amendment control sheet
AS 2252.2—2009
Amendment No. 1 (2010)
Correction
Cited references in this standard
[Current]
High efficiency particulate air (HEPA) filters — Classification, construction and performance
[Superseded]
Cleanrooms, workstations, safety cabinets and pharmaceutical isolators — Methods of test, Method 26: Determination of air barrier containment of laminar flow safety cabinets — Potassium iodidediscus test
[Superseded]
Degrees of protection provided by enclosures for electrical equipment (IP Code)
[Pending Revision]
Controlled environments, Part 4: Biological safety cabinets Classes I and II — Installation and use (BS 5726:2005, MOD)
[Current]
Controlled environments, Part 5: Cytotoxic drug safety cabinets (CDSC) — Design, construction, installation, testing and use