Standard
Track updates
iconCreated with Sketch.

AS 2050:2018

[Current]

Installation of Roof Tiles

This Standard sets out requirements for the placement and installing of roof tiles of the types specified in AS 2049. The installation methods described in this Standard apply only to tiled roofs of buildings that are intended for domestic, commercial or light industrial purposes for wind classifications N1-N6 and C1-C4 inclusive.
Published: 29/06/2018
Pages: 24
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
1 Scope and general
1.1 Scope
1.2 Application
1.3 Normative references
1.4 Definitions
1.5 Requirements for the completed roof
1.5.1 Loading
1.5.2 Weather resistance
1.5.3 Adhesive mechanical fastening
2 Materials
2.1 Sarking
2.1.1 Pliable building membranes
2.1.2 Rigid or semi-rigid materials
2.2 Roof battens
2.2.1 Timber battens
2.2.2 Steel battens
2.3 Flexible pointing
2.4 Installing systems
2.4.1 General
2.4.2 Installing requirements
2.4.3 Corrosion protection and material compatibility
3 Installation
3.1 Sarking
3.1.1 General
3.1.2 Anti-ponding device/board
3.1.3 Damage
3.1.4 Requirements for roofs without general sarking
3.1.5 Long rafter lengths
3.2 Battens
3.2.1 General
3.2.2 First course of the roof tiles
3.2.3 Batten alignment
3.2.4 Batten spacing
3.2.5 Batten installation
3.2.6 Fixing steel battens to steel trusses or rafters
3.2.7 Batten joints
3.3 Tiles and ancillaries
3.3.1 General
3.3.2 Sarked roofs
3.3.3 Set out
3.3.4 Soldier courses
3.3.5 Gable tiles
3.3.6 Eaves tiles
3.3.7 Hip tiles
3.3.8 Barge capping tiles
3.3.9 Cut tiles in cyclonic regions
3.4 Bedding and pointing
3.5 Tiling over separating walls
3.6 Workmanship
Appendix A
Appendix B
Appendix C
Bibliography
Cited references in this standard
[Current]
Structural design actions, Part 2: Wind actions
[Current]
Methods of testing roof tiles, Method 8: Adhesive mechanical fasteners — Flexible pointing
[Current]
Methods of testing roof tiles, Method 9: Determination of dynamic weather resistance
[Current]
Wind loads for housing
[Current]
Structural design actions, Part 1: Permanent, imposed and other actions
Content history
[Superseded]
DR AS 2050:2016
AS 2050-2002 inc AMD 1 and 2

One-time Purchase

Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^

$141.91 AUD

Inclusive of GST
Format *
iconCreated with Sketch.
Web Reader
Licenses *
iconCreated with Sketch.
1 user
Total$141.91 AUD
Add to Cart
IMPORTANT