Standard
Track updates
iconCreated with Sketch.

AS 1603.11:2018

[Current]

Automatic fire detection and alarm systems, Part 11: Visual warning devices

The objective of this Standard is to provide manufacturers and designers of fire detection and alarm systems with requirements for the design and performance of visual warning devices intended to provide supplementary information in fire detection, warning, control and intercom systems.
Published: 20/12/2018
Pages: 12
Table of contents
Cited references
Content history
Table of contents
Header
About this publication
Preface
1 Scope and general
1.1 Scope
1.2 Application
1.3 Normative references
1.4 Terms and definitions
2 Requirements
2.1 General
2.2 Luminance requirements for internally illuminated, fixed message type VWD
2.2.1 Mean luminance
2.2.2 Luminance ratios
2.2.3 Uniformity
2.3 Luminance requirements for LED matrix, fixed message type VWD
2.3.1 Mean luminance
2.3.2 Uniformity
2.4 Luminance requirements for programmable message type VWD
2.4.1 Mean luminance
2.4.2 Uniformity
2.4.3 Flashing messages
2.4.4 Fire safety text messages
2.5 Maximum rated viewing distance
2.6 Countdown timer — optional function
2.7 Ancillary functions — optional
2.8 Supervision of detachable devices
2.9 Environmental classification
2.10 Flash rate — optional function
2.11 Synchronization — optional function
2.12 Remotely controlled VWD
2.13 Construction
2.13.1 Visual warning text contrast
2.13.2 Connecting facilities
2.13.3 Materials
2.13.4 Ingress protection
2.13.5 Access
2.13.6 Adjustments
2.14 Requirements for software controlled devices
3 Testing
3.1 General
3.1.1 Test specimens
3.1.2 Test schedule
3.2 Performance and variation in supply parameters
3.2.1 Objective of test
3.2.2 Test procedure
3.2.3 Requirements
3.3 Dry heat (operational)
3.3.1 General
3.3.2 Conditioning
3.4 Cold (operational)
3.4.1 General
3.4.2 Conditioning
3.5 Damp heat, cyclic (operational)
3.5.1 General
3.5.2 Conditioning
3.6 Damp heat, steady-state (endurance)
3.6.1 General
3.6.2 Conditioning
3.7 Electromagnetic compatibility (EMC) immunity tests (operational)
3.7.1 General
3.7.2 Conditioning
3.8 Exposure to simulated solar radiation (endurance) (option with requirements)
3.8.1 General
3.8.2 Objective of test
3.8.3 Test procedure
3.8.4 State of the specimen during exposure
3.8.5 Exposure
3.8.6 Measurements during exposure
3.8.7 Final measurements
3.8.8 Requirements
4 Test report
5 Markings
6 Data
Bibliography
Cited references in this standard
[Current]
Corrigendum 1 - Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
[Current]
Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems
[Current]
Corrigendum 1 - Amendment 2 - Degrees of protection provided by enclosures (IP Code)
[Current]
Corrigendum 1 - Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
[Current]
Fire detection and alarm systems, Part 23: Visual alarm devices
Content history
[Superseded]
DR AS 1603.11:2018

One-time Purchase

Access via web browser on any device
One-time purchase
Single publication
Offline access via PDF^

$83.52 AUD

Inclusive of GST
Format *
iconCreated with Sketch.
Web Reader
Licenses *
iconCreated with Sketch.
1 user
Total$83.52 AUD
Add to Cart
IMPORTANT